ALITA
INDUSTRIES

AL-15A.PVM


Performance Curves
× 15L
× Multiple
Specification
Model AL-15A.18PVM
Operating Voltage 18VDC
Rated Performance * 15 LPM @ 10 kPa
0.53 CFM @ 1.4 psig
Rated Current 0.73 A
Rated Power 13 W
Maximum Current (at 20Vin) 0.8 A
Maximum Power (at 20Vin) 16 W
Operating Voltage Range 5 ~ 20VDC
   
Nominal 12V Solar Panel Selection Parameters:  
Maximum Power Point Voltage at NOCT (Vmpp) ≤ 18 V
Maximum Power Point Current at NOCT (Impp) ≥ 1.0 A
Maximum Power Voltage at STC (Vmp) ¤ < 20 V
Open Circuit Voltage at STC (Voc) < 25 V
Model AL-15A.18PVM
Operating Voltage 18VDC
Rated Performance * 15 LPM @ 10 kPa
0.53 CFM @ 1.4 psig
Rated Current 0.73 A
Rated Power 13 W
Maximum Current (at 20Vin) 0.8 A
Maximum Power (at 20Vin) 16 W
Operating Voltage Range 5 ~ 20VDC
   
Nominal 12V Solar Panel Selection Parameters:
Maximum Power Point Voltage ≤ 18 V at NOCT (Vmpp)
Maximum Power Point Current ≥ 1.0 A at NOCT (Impp)
Maximum Power Voltage < 20 V at STC (Vmp) ¤
Open Circuit Voltage < 25 V at STC (Voc)

* Performance at specific reference pressure load (e.g. 10 kPa, 15 kPa, or 20 kPa)
† Vmpp at NOCT should not exceed the pump's designed operating voltage
‡ Impp at NOCT should be at least 30% more than required by the specific pump at Rated Performance
¤ Vmpp at STC should not exceed 10% of pump's designed operating voltage
Output performance influence by supply voltage and current capacities
Specifications and performance data are subject to change without notice

 

Model Description:
AL-  15A  .  18  PVM
             
Rated Performance
    15A: 15 LPM @ 10 kPa
    25M: 25 LPM @ 10 kPa
    35M: 35 LPM @ 10 kPa
   
Operating Voltage
    18: 18Vdc - direct, for nominal 12V solar panel, 30W ~ 60W