ALITA
INDUSTRIES

AL-60A.PVM & AL-80A.PVM Series


Performance Curves
× 80L
× 80LmV
× 60L
Specification
Model AL-80A.30PVM AL-60A.30PVM
Operating Voltage 30VDC 30VDC
Rated Performance * 80 LPM @ 15 kPa
2.8 CFM @ 2.2 psig
60 LPM @ 15 kPa
2.1 CFM @ 2.2 psig
Rated Current 3.7 A 2.3 A
Rated Power 111 W 69 W
Maximum Current 4.2 A 2.7 A
Maximum Power 126 W 81 W
Operating Voltage Range 5 ~ 33VDC 5 ~ 33VDC
     
Solar Panel (60-cell) Selection Parameters:    
Maximum Power Point Voltage at NOCT (Vmpp) ≤ 30 V ≤ 30 V
Maximum Power Point Current at NOCT (Impp) ≥ 4.8 A ≥ 3.0 A
Maximum Power Point Voltage at STC (Vmpp) ¤ < 33 V < 33 V
Open Circuit Voltage at STC (Voc) < 45 V < 45 V
Model AL-80A.30PVM
Operating Voltage 30VDC
Rated Performance 80 LPM @ 15 kPa
2.8 CFM @ 2.2 psig
Rated Current 3.7 A
Rated Power 111 W
Maximum Power 126 W
Maximum Current 4.2 A
Operating Voltage Range 5 ~ 33VDC
   
Solar Panel (60-cell) Selection Parameters:
Maximum Power Point Voltage (Vmpp) ≤ 30 V at NOCT
Maximum Power Point Current (Impp) ≥ 4.8 A at NOCT
Maximum Power Point Voltage (Vmpp) < 33 V at STC ¤
Open Circuit Voltage (Voc) < 45 V at STC
 
Model AL-60A.30PVM
Operating Voltage 30VDC
Rated Performance 60 LPM @ 15 kPa
2.1 CFM @ 2.2 psig
Rated Current 2.3 A
Rated Power 69 W
Maximum Current 2.7 A
Maximum Power 81 W
Operating Voltage Range 5 ~ 33VDC
   
Solar Panel (60-cell) Selection Parameters:
Maximum Power Point Voltage (Vmpp) ≤ 30 V at NOCT
Maximum Power Point Current (Impp) ≥ 3.0 A at NOCT
Maximum Power Point Voltage (Vmpp) < 33 V at STC ¤
Open Circuit Voltage (Voc) < 45 V at STC

* Performance at specific reference pressure load (e.g. 15 kPa, 18 kPa or 20 kPa)
† Vmpp at NOCT should not exceed the pump's designed operating voltage
‡ Impp at NOCT should be at least 30% more than required by the specific pump at Rated Performance
¤ Vmpp at STC should not exceed 10% of pump's designed operating voltage
Output performance influence by supply voltage and current capacities
Specifications and performance data are subject to change without notice

 

Model Description:
AL-  80A  .  30  PVM  

Rated Performance
             
80A: 80 LPM @ 15 kPa
60A: 60 LPM @ 15 kPa
40A: 40 LPM @ 15 kPa

Operating Voltage
30: 30Vdc - for 60-cell solar panel with NOCT Vmpp: 28~30V (nominal 20V)
36: 36Vdc - for 72-cell solar panel with NOCT Vmpp: 33~36V (nominal 24V)