ALITA
INDUSTRIES

AL-120/150/200.PVM Series


Performance Curves
× 120L
× 150L
× 200L
Specification
Model AL-120.30PVM AL-150.30PVM AL-200.30PVM
Operating Voltage 30VDC 30VDC 30VDC
Rated Performance * 120 LPM @ 18 kPa
4.2 CFM @ 2.6 psig
150 LPM @ 20 kPa
5.3 CFM @ 2.9 psig
200 LPM @ 20 kPa
7.0 CFM @ 2.9 psig
Rated Current 4.2 A 5.4 A 7.2 A
Rated Power 126 W 162 W 216 W
Maximum Current 5.2 A 7.5 A 9.3 A
Maximum Power 155 W 225 W 279 W
Operating Voltage Range 5 ~ 33VDC 5 ~ 33VDC 5 ~ 33VDC
       
Solar Panel (60-cell) Selection Parameters:      
Maximum Power Point Voltage at NOCT (Vmpp) ≤ 30 V ≤ 30 V ≤ 30 V
Maximum Power Point Current at NOCT (Impp) ≥ 5.5 A ≥ 7.0 A ≥ 9.4 A
Maximum Power Point Voltage at STC (Vmpp) ¤ < 33 V < 33 V < 33 V
Open Circuit Voltage at STC (Voc) < 45 V < 45 V < 45 V
Model AL-120.30PVM
Operating Voltage 30VDC
Rated Performance 120 LPM @ 18 kPa
4.2 CFM @ 2.6 psig
Rated Current 4.2 A
Rated Power 126 W
Maximum Power 5.2 A
Maximum Current 155 W
Operating Voltage Range 5 ~ 33VDC
   
Solar Panel (60-cell) Selection Parameters:  
Maximum Power Point Voltage at NOCT (Vmpp) ≤ 30 V
Maximum Power Point Current at NOCT (Impp) ≥ 5.5 A
Maximum Power Point Voltage at STC (Vmpp) ¤ < 33 V
Open Circuit Voltage at STC (Voc) < 45 V
 
Model AL-150.30PVM
Operating Voltage 30VDC
Rated Performance 150 LPM @ 20 kPa
5.3 CFM @ 2.9 psig
Rated Current 5.4 A
Rated Power 162 W
Maximum Current 7.5 A
Maximum Power 225 W
Operating Voltage Range 5 ~ 33VDC
   
Solar Panel (60-cell) Selection Parameters:  
Maximum Power Point Voltage at NOCT (Vmpp) ≤ 30 V
Maximum Power Point Current at NOCT (Impp) ≥ 7.0 A
Maximum Power Point Voltage at STC (Vmpp) ¤ < 33 V
Open Circuit Voltage at STC (Voc) < 45 V
 
Model AL-200.30PVM
Operating Voltage 30VDC
Rated Performance 200 LPM @ 20 kPa
7.0 CFM @ 2.9 psig
Rated Current 7.2 A
Rated Power 216 W
Maximum Current 9.3 A
Maximum Power 279 W
Operating Voltage Range 5 ~ 33VDC
   
Solar Panel (60-cell) Selection Parameters:  
Maximum Power Point Voltage at NOCT (Vmpp) ≤ 30 V
Maximum Power Point Current at NOCT (Impp) ≥ 9.4 A
Maximum Power Point Voltage at STC (Vmpp) ¤ < 33 V
Open Circuit Voltage at STC (Voc) < 45 V

* Performance at specific reference pressure load (e.g. 15 kPa, 18 kPa or 20 kPa)
† Vmpp at NOCT should not exceed the pump's designed operating voltage
‡ Impp at NOCT should be at least 30% more than required by the specific pump at Rated Performance
¤ Vmpp at STC should not exceed 10% of pump's designed operating voltage
Output performance influence by supply voltage and current capacities
Specifications and performance data are subject to change without notice

 

Model Description:
AL-  150  .  30  PVM
             
Rated Performance
    120: 120 LPM @ 18 kPa
    150: 150 LPM @ 20 kPa
    200: 200 LPM @ 20 kPa
   
Operating Voltage
    36: 36Vdc - direct, for 72-cell solar panel with NOCT Vmpp: 33~36V
    30: 30Vdc - direct, for 60-cell solar panel with NOCT Vmpp: 28~30V
    28: 28Vdc - direct, for 60-cell solar panel with NOCT Vmpp: 26~28V
    24: 24Vdc - indirect, for DC power supplies with 24Vout