| Model | AL-120.30PVM | AL-150.30PVM | AL-200.30PVM |
|---|---|---|---|
| Operating Voltage | 30VDC | 30VDC | 30VDC |
| Rated Performance * | 120 LPM @ 18 kPa 4.2 CFM @ 2.6 psig |
150 LPM @ 20 kPa 5.3 CFM @ 2.9 psig |
200 LPM @ 20 kPa 7.0 CFM @ 2.9 psig |
| Rated Current | 4.2 A | 5.4 A | 7.2 A |
| Rated Power | 126 W | 162 W | 216 W |
| Maximum Current | 5.2 A | 7.5 A | 9.3 A |
| Maximum Power | 155 W | 225 W | 279 W |
| Operating Voltage Range | 5 ~ 33VDC | 5 ~ 33VDC | 5 ~ 33VDC |
| Solar Panel (60-cell) Selection Parameters: | |||
| Maximum Power Point Voltage at NOCT (Vmpp) † | ≤ 30 V | ≤ 30 V | ≤ 30 V |
| Maximum Power Point Current at NOCT (Impp) ‡ | ≥ 5.5 A | ≥ 7.0 A | ≥ 9.4 A |
| Maximum Power Point Voltage at STC (Vmpp) ¤ | < 33 V | < 33 V | < 33 V |
| Open Circuit Voltage at STC (Voc) | < 45 V | < 45 V | < 45 V |
| Model | AL-120.30PVM |
|---|---|
| Operating Voltage | 30VDC |
| Rated Performance | 120 LPM @ 18 kPa 4.2 CFM @ 2.6 psig |
| Rated Current | 4.2 A |
| Rated Power | 126 W |
| Maximum Power | 5.2 A |
| Maximum Current | 155 W |
| Operating Voltage Range | 5 ~ 33VDC |
| Solar Panel (60-cell) Selection Parameters: | |
| Maximum Power Point Voltage at NOCT (Vmpp) † | ≤ 30 V |
| Maximum Power Point Current at NOCT (Impp) ‡ | ≥ 5.5 A |
| Maximum Power Point Voltage at STC (Vmpp) ¤ | < 33 V |
| Open Circuit Voltage at STC (Voc) | < 45 V |
| Model | AL-150.30PVM |
| Operating Voltage | 30VDC |
| Rated Performance | 150 LPM @ 20 kPa 5.3 CFM @ 2.9 psig |
| Rated Current | 5.4 A |
| Rated Power | 162 W |
| Maximum Current | 7.5 A |
| Maximum Power | 225 W |
| Operating Voltage Range | 5 ~ 33VDC |
| Solar Panel (60-cell) Selection Parameters: | |
| Maximum Power Point Voltage at NOCT (Vmpp) † | ≤ 30 V |
| Maximum Power Point Current at NOCT (Impp) ‡ | ≥ 7.0 A |
| Maximum Power Point Voltage at STC (Vmpp) ¤ | < 33 V |
| Open Circuit Voltage at STC (Voc) | < 45 V |
| Model | AL-200.30PVM |
| Operating Voltage | 30VDC |
| Rated Performance | 200 LPM @ 20 kPa 7.0 CFM @ 2.9 psig |
| Rated Current | 7.2 A |
| Rated Power | 216 W |
| Maximum Current | 9.3 A |
| Maximum Power | 279 W |
| Operating Voltage Range | 5 ~ 33VDC |
| Solar Panel (60-cell) Selection Parameters: | |
| Maximum Power Point Voltage at NOCT (Vmpp) † | ≤ 30 V |
| Maximum Power Point Current at NOCT (Impp) ‡ | ≥ 9.4 A |
| Maximum Power Point Voltage at STC (Vmpp) ¤ | < 33 V |
| Open Circuit Voltage at STC (Voc) | < 45 V |
* Performance at specific reference pressure load (e.g. 15 kPa, 18 kPa or 20 kPa)
† Vmpp at NOCT should not exceed the pump's designed operating voltage
‡ Impp at NOCT should be at least 30% more than required by the specific pump at Rated Performance
¤ Vmpp at STC should not exceed 10% of pump's designed operating voltage
Output performance influence by supply voltage and current capacities
Specifications and performance data are subject to change without notice